Request A Quote
Talk to us for inquiries about product models, accessories, stock, discounts, tariffs, shipping, and delivery time.
HiPNUC | SKU:
HiPNUC HI13S Sensor
Regular price
$165.00
Unit price
What's Included:
1 x HiPNUC HI13S Sensor
HiPNUC HI13S Sensor - HI13S2-USB-000 IMU/VRU (High-Performance Low Noise) is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
- We automatically select the most cost-effective carrier from China for each destination country.
- Shipping rates are dynamically calculated based on real-time quotes. Final rates may vary due to promotional offers or carrier adjustments.
HiPNUC HI13S Sensor - HI13S2-USB-000 IMU/VRU (High-Performance Low Noise) is backordered and will ship as soon as it is back in stock.
Bulk purchase and academic discounts are available. Quote us now.
Product Detail
Specification
Gyroscope
Measurement Range (Gyroscope)
±250°/s, ±500°/s, ±1000°/s, ±2000°/s, ±4000°/s (Default: ±2000°/s)
Resolution (Gyroscope)
16 bit (Typical: 20 bit)
Scale Factor Error
<600 ppm (Typical: 1200 ppm, RMS, Condition: 100°/s Rotation)
Nonlinearity (Gyroscope)
±0.05 %FS
Noise Density (Gyroscope)
0.0025 °/s/√Hz (Condition: Bandwidth 10 Hz)
3dB Bandwidth (Gyroscope)
80 Hz (Typical: 400 Hz)
Zero-Rate Output
<0.1 °/s (Typical: ±0.45 °/s)
Sampling Rate (Gyroscope)
1000 Hz
Bias Instability (Allan Variance)
X: 4°/h (Typ: 6°/h), Y: 1.5°/h (Typ: 2.5°/h), Z: 1.7°/h (Typ: 4°/h) (Typ: 1σ, Max: 3σ)
Bias Stability (10s Averaging)
X: 10°/h (Typ: 16°/h), Y: 4°/h (Typ: 7°/h), Z: 5°/h (Typ: 13°/h) (Typ: 1σ, Max: 3σ)
Bias Repeatability
X: 11°/h (Typ: 35°/h), Y: 10°/h (Typ: 30°/h), Z: 9°/h (Typ: 20°/h)
Bias Full-Temperature Variation (Gyroscope)
0.07 °/s (Typical: 0.15 °/s, Condition: -40℃ ~ 85℃)
Acceleration Sensitivity
0.05 °/s/g (XYZ Axis)
Accelerometer
Measurement Range (Accelerometer)
±2g, ±8g, ±16g, ±32g (Default: ±16g)
Resolution (Accelerometer)
16 bit (Typical: 20 bit)
Initial Bias
1 mg (Typical: 2 mg, Typical Value: RMS)
Nonlinearity (Accelerometer)
±0.01 %FS
Noise Density (Accelerometer)
0.05 mg/√Hz (Typical: 0.07 mg/√Hz, Condition: Bandwidth 10 Hz)
3dB Bandwidth (Accelerometer)
90 Hz (Typical: 400 Hz)
Sampling Rate (Accelerometer)
1000 Hz
Bias Instability (Accelerometer)
X: 0.012 mg (Typ: 0.02 mg), Y: 0.009 mg (Typ: 0.015 mg), Z: 0.016 mg (Typ: 0.022 mg) (Typ: 1σ, Max: 3σ)
Bias Stability (Accelerometer, 10s Averaging)
X: 0.032 mg (Typ: 0.055 mg), Y: 0.022 mg (Typ: 0.032 mg), Z: 0.048 mg (Typ: 0.082 mg) (Typ: 1σ, Max: 3σ)
Bias Repeatability (Accelerometer)
X: 0.1 mg (Typ: 0.3 mg), Y: 0.06 mg (Typ: 0.2 mg), Z: 0.1 mg (Typ: 0.2 mg)
Random Walk (Allan Variance)
0.019 m/s/√h (Typical: 0.03 m/s/√h, XYZ Axis, Typ: 1σ, Max: 3σ)
Bias Full-Temperature Variation (Accelerometer)
XY Axis: 2 mg (Typical: 5 mg), Z Axis: 6 mg (Typical: 15 mg), Condition: -40℃ ~ 85℃
Magnetometer
Measurement Range (Magnetometer)
±2000 μT
Noise (Magnetometer)
0.19 μT (Typical: 0.45 μT)
Nonlinearity (Magnetometer)
±10 μT (Typical: ±20 μT)
Barometer
Measurement Range (Barometer)
300 hPa ~ 1200 hPa
Resolution (Barometer)
0.006 hPa
Accuracy (Barometer)
±0.06 hPa
Temperature Sensor
Measurement Range (Temperature)
-40℃ ~ 85℃
Bias Error (Temperature)
±5℃
Attitude Accuracy
Pitch/Roll (Static)
0.1° (Typical: 0.15°)
Pitch/Roll (Dynamic)
0.2° (Typical: 0.3°)
Heading Angle (AHRS)
2° (Typical: 3°)
Heading Angle Static Drift (6-DoF)
0.15° (Typical: 0.2°, Condition: Static for 2h)
Heading Angle Dynamic Drift (6-DoF)
±5° (Typical: ±10°)
Heading Angle Rotation Error (6-DoF)
0.4° (Condition: 100°/s Rotation)
Technical Document