Request A Quote
Talk to us for inquiries about product models, accessories, stock, discounts, tariffs, shipping, and delivery time.
HiPNUC | SKU:
HiPNUC HI13M Sensor
Regular price
$80.00
Unit price
What's Included:
1 x HiPNUC HI13M Sensor
HiPNUC HI13M Sensor - HI13M0-USB-000 IMU/VRU (Basic Version) is backordered and will ship as soon as it is back in stock.
Delivery and Shipping
Delivery and Shipping
- We automatically select the most cost-effective carrier from China for each destination country.
- Shipping rates are dynamically calculated based on real-time quotes. Final rates may vary due to promotional offers or carrier adjustments.
HiPNUC HI13M Sensor - HI13M0-USB-000 IMU/VRU (Basic Version) is backordered and will ship as soon as it is back in stock.
Bulk purchase and academic discounts are available. Quote us now.
Product Detail
Specification
Gyroscope:
Measurement Range
±250°/s, ±500°/s, ±1000°/s, ±2000°/s (Default: ±2000°/s)
Resolution
16 bit
Scale Factor Error
<600 ppm (Typical: 850 ppm, RMS, Condition: 100°/s Rotation)
Nonlinearity
±0.05 %FS
Noise Density
0.014 °/s/√Hz (Condition: Bandwidth 47 Hz)
3dB Bandwidth
80 Hz (Typical: 200 Hz)
Zero-Rate Output
<0.1 °/s (Typical: ±0.45 °/s)
Sampling Rate
1000 Hz
Bias Instability (Allan Variance)
X: 2.5°/h (Typ: 4°/h), Y: 3.2°/h (Typ: 5.5°/h), Z: 3°/h (Typ: 5.5°/h) (Typ: 1σ, Max: 3σ)
Bias Stability (10s Averaging)
X: 10°/h (Typ: 14°/h), Y: 13°/h (Typ: 17°/h), Z: 10°/h (Typ: 13°/h) (Typ: 1σ, Max: 3σ)
Bias Repeatability
X: 20°/h (Typ: 36°/h), Y: 36°/h (Typ: 61°/h), Z: 16°/h (Typ: 25°/h)
Bias Full-Temperature Variation
0.07 °/s (Typical: 0.15 °/s, Condition: -40℃ ~ 85℃)
Acceleration Sensitivity
0.05 °/s/g (XYZ Axis)
Accelerometer:
Measurement Range
±3g, ±6g, ±12g, ±24g (Default: ±12g)
Resolution
16 bit
Initial Bias
1 mg (Typical: 2 mg, Typical Value: RMS)
Nonlinearity
±0.01 %FS
Noise Density
0.16 mg/√Hz (Typical: 0.2 mg/√Hz)
3dB Bandwidth
90 Hz (Typical: 200 Hz)
Sampling Rate
1000 Hz
Bias Instability (Allan Variance)
X: 0.021 mg (Typ: 0.035 mg), Y: 0.032 mg (Typ: 0.065 mg), Z: 0.023 mg (Typ: 0.03 mg) (Typ: 1σ, Max: 3σ)
Bias Stability (10s Averaging)
X: 0.068 mg (Typ: 0.1 mg), Y: 0.09 mg (Typ: 0.19 mg), Z: 0.07 mg (Typ: 0.1 mg) (Typ: 1σ, Max: 3σ)
Bias Repeatability
X: 0.22 mg (Typ: 0.4 mg), Y: 0.15 mg (Typ: 0.21 mg), Z: 0.12 mg (Typ: 0.2 mg)
Random Walk (Allan Variance)
0.09 m/s/√h (Typical: 0.11 m/s/√h, XYZ Axis, Typ: 1σ, Max: 3σ)
Bias Full-Temperature Variation
2 mg (Typical: 5 mg, XYZ Axis, Condition: -40℃ ~ 85℃)
Magnetometer:
Measurement Range
±2000 μT
Noise
0.19 μT (Typical: 0.45 μT)
Nonlinearity
±10 μT (Typical: ±20 μT)
Barometer:
Measurement Range
300 hPa ~ 1200 hPa
Resolution
0.006 hPa
Accuracy
±0.06 hPa
Temperature Sensor:
Measurement Range
-40℃ ~ 85℃
Bias Error
±5℃
Attitude Accuracy:
Pitch/Roll (Static)
0.1° (Typical: 0.15°)
Pitch/Roll (Dynamic)
0.2° (Typical: 0.3°)
Heading Angle (AHRS)
2° (Typical: 3°)
Heading Angle Static Drift (6-DoF)
0.15° (Typical: 0.2°, Condition: Static for 2h)
Heading Angle Dynamic Drift (6-DoF)
±10° (Typical: ±18°)
Heading Angle Rotation Error (6-DoF)
0.3° (Condition: 100°/s Rotation)